Selecting main technical specifications of the data aquisition system to improve the accuracy of using the electric response parameters / D. D. Dann, M. V. Petrov, P. I. Fedotov
Уровень набора: (RuTPU)RU\TPU\network\3526, Journal of Physics: Conference SeriesЯзык: английский.Резюме или реферат: Based on the conducted experimental studies, the necessary parameters were selected to provide reliable testing of concrete defects. The measuring system must have: input sensitivity of the receiving electromagnetic channel of at least100 µV, the working frequency range of 1–120 kHz; the sampling frequency of 500 kHz, as well as a device that allows fast Fourier transform. The registration of the electrical response during an elastic impact should be made by a differential electric sensor, which allows measurements under conditions of external electromagnetic interference..Примечания о наличии в документе библиографии/указателя: [References: 4 tit.].Тематика: электронный ресурс | труды учёных ТПУ | электрический отклик | параметры | технические характеристики Ресурсы он-лайн:Щелкните здесь для доступа в онлайнНет реальных экземпляров для этой записи
Title screen
[References: 4 tit.]
Based on the conducted experimental studies, the necessary parameters were selected to provide reliable testing of concrete defects. The measuring system must have: input sensitivity of the receiving electromagnetic channel of at least100 µV, the working frequency range of 1–120 kHz; the sampling frequency of 500 kHz, as well as a device that allows fast Fourier transform. The registration of the electrical response during an elastic impact should be made by a differential electric sensor, which allows measurements under conditions of external electromagnetic interference.
Для данного заглавия нет комментариев.
Личный кабинет оставить комментарий.