Experimental study of positron production from a 2.55-mm-thick silicon crystal target using 8-GeV electron beams with high-bunch charges / T. Suwada [и др.]

Уровень набора: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms = 2006Альтернативный автор-лицо: Suwada, T., 070;Furukawa, K., 070;Kamitani, T., 070;Satoh, M., 070;Sugimura, T., 070;Umemori, K., 070;Okuno, H., 070;Hamatsu, R., 070;Yoshida, K., 070;Potylitsyn, A. P., Russian physicist, Professor of the TPU, 1945-, Alexander Petrovich, 070;Tropin, I. S., 070;Chehab, R., 070Язык: английский.Страна: .Резюме или реферат: We have investigated quenching phenomena of channeling radiation through positron production from a silicon crystal hit by a single-bunch electron beam with high-bunch charge at the 8-GeV electron/positron injector linac. The crystal axis, 1 1 0, was aligned to the electron beam with a precise goniometer, and positrons produced in the forward direction with a momentum of 20 MeV/c were detected with a magnetic spectrometer. Positron yields were measured by varying the charge in a bunch with a typical bunch length of 10 ps from 0.1 nC to 2 nC. The corresponding instantaneous current density ranged from 0.15 × 104 to 1.2 × 104 A/cm2. The results show that, at these current densities, the positron yield is proportional to the bunch charge within the experimental accuracy, which implies that no non-linear phenomena are observed in channeling radiation..Аудитория: .Тематика: труды учёных ТПУ
Тэги из этой библиотеки: Нет тэгов из этой библиотеки для этого заглавия. Авторизуйтесь, чтобы добавить теги.
Оценка
    Средний рейтинг: 0.0 (0 голосов)
Нет реальных экземпляров для этой записи

We have investigated quenching phenomena of channeling radiation through positron production from a silicon crystal hit by a single-bunch electron beam with high-bunch charge at the 8-GeV electron/positron injector linac. The crystal axis, 1 1 0, was aligned to the electron beam with a precise goniometer, and positrons produced in the forward direction with a momentum of 20 MeV/c were detected with a magnetic spectrometer. Positron yields were measured by varying the charge in a bunch with a typical bunch length of 10 ps from 0.1 nC to 2 nC. The corresponding instantaneous current density ranged from 0.15 × 104 to 1.2 × 104 A/cm2. The results show that, at these current densities, the positron yield is proportional to the bunch charge within the experimental accuracy, which implies that no non-linear phenomena are observed in channeling radiation.

Для данного заглавия нет комментариев.

оставить комментарий.