Determining direct measures of performance based on the location of zeros and pole of the transfer function = Определение прямых показателей качества на основе расположения нулей и полюсов передаточной функции / S. V. Efimov, M. I. Pushkarev
Уровень набора: Optoelectronics, Instrumentation and Data ProcessingЯзык: английский.Страна: Россия.Резюме или реферат: An analysis is made of the effect of zeros and poles of a closed-loop automatic control system on its direct measures of performance: overcontrol and control time. The necessity of determining the dominant poles in the root-locus plane is shown. A criterion for the ?-dominance of the components of the transient function of automatic control system is presented. A method for calculating direct measures of performance based on the location of zeros and poles of the system is developed. Numerical examples are considered..Примечания о наличии в документе библиографии/указателя: [References: p. 302 (5 tit.)].Аудитория: .Тематика: электронный ресурс | труды учёных ТПУ Ресурсы он-лайн:Щелкните здесь для доступа в онлайнНет реальных экземпляров для этой записи
Title screen
[References: p. 302 (5 tit.)]
An analysis is made of the effect of zeros and poles of a closed-loop automatic control system on its direct measures of performance: overcontrol and control time. The necessity of determining the dominant poles in the root-locus plane is shown. A criterion for the ?-dominance of the components of the transient function of automatic control system is presented. A method for calculating direct measures of performance based on the location of zeros and poles of the system is developed. Numerical examples are considered.