Experience of Pseudospark Switch Operation in Pulse Power Applications / N. V. Voitenko [et al.]
Уровень набора: (RuTPU)RU\TPU\network\3526, Journal of Physics: Conference SeriesЯзык: английский.Страна: .Резюме или реферат: The paper demonstrates the results of TDI1-200k/25SN-P pseudospark switch (PSS) developed by Russian company "Pulsed Technologies Ltd" application. PSS was used in pulsed power unit intended for electric-discharge fracture of rocks and concrete blocks and splitting off from monolith. The pulsed power unit has a pulse current generator with the capacity of 560 [mu]F, stored energy of up to 63 kJ, operating voltage of up to15 kV, current pulse amplitude of up to 200 kA and pulse duration more than 200 [mu]sec. The study also shows the current waveforms determined in the short-circuit experiment of the pulse current generator and in the experiments of the electric-discharge fragmentation of concrete at the charging voltage of 13 kV. PSS was operated in ringing single-pulse mode with the exceedance of more than two maximum permissible parameters: current pulse amplitude, current pulse duration and maximum pulse energy. Internal electrode erosion of PSS is shown and possible reasons of asymmetric current feed are discussed..Примечания о наличии в документе библиографии/указателя: [References: 11 tit.].Аудитория: .Тематика: труды учёных ТПУ | электронный ресурс | переключатели | импульсная мощность | питание | электрические разряды | короткие замыкания | бетоны | блоки Ресурсы он-лайн:Щелкните здесь для доступа в онлайн | Щелкните здесь для доступа в онлайнTitle screen
[References: 11 tit.]
The paper demonstrates the results of TDI1-200k/25SN-P pseudospark switch (PSS) developed by Russian company "Pulsed Technologies Ltd" application. PSS was used in pulsed power unit intended for electric-discharge fracture of rocks and concrete blocks and splitting off from monolith. The pulsed power unit has a pulse current generator with the capacity of 560 [mu]F, stored energy of up to 63 kJ, operating voltage of up to15 kV, current pulse amplitude of up to 200 kA and pulse duration more than 200 [mu]sec. The study also shows the current waveforms determined in the short-circuit experiment of the pulse current generator and in the experiments of the electric-discharge fragmentation of concrete at the charging voltage of 13 kV. PSS was operated in ringing single-pulse mode with the exceedance of more than two maximum permissible parameters: current pulse amplitude, current pulse duration and maximum pulse energy. Internal electrode erosion of PSS is shown and possible reasons of asymmetric current feed are discussed.
Для данного заглавия нет комментариев.