Testing a thermoacoustic sensor of high-power microwave pulses = Испытания термоакустического датчика мощных микроволновых импульсов / V. G. Andreev [et al.]

Уровень набора: Radiophysics and Quantum Electronics = 1965-Альтернативный автор-лицо: Andreev, V. G.;Vdovin, V. A.;El'chaninov, A. A., Anton Aleksandrovich;Afanas’ev, K. V.;Klimov, A. I., specialist in the field of electronics, Associate Professor of Tomsk Polytechnic University, Candidate of physical and mathematical sciences, 1955-, Aleksey IvanovichЯзык: английский ; резюме, eng.Страна: Россия.Резюме или реферат: We present the results of testing a new thermoacoustic sensor designed to detect microwave pulses having durations from 3 to 120 ns at wavelengths of 0.8 and 3 cm. Operation of the sensor is based on the effect of generation of acoustic signals during absorption of microwave pulses in a radiotransparent substrate–absorber–liquid layered structure . A thin nanometer-thick film deposited on a substrate is used as an absorber. Microwaves are converted to an acoustic pulse in the film and the adjacent liquid. The pulse is received by a wideband acoustic receiver and then recorded by a digital oscilloscope. It is shown that for a pulse duration of 120 ns, the shape of the signal recorded by the thermoacoustic sensor completely corresponds to the signal of a tube-diode detector of microwave pulses. The response of the thermoacoustic sensor to shorter pulses (3 and 5 ns long) is a pulse with a duration of 18 ns which is determined by a limited frequency band of the acoustic receiver..Примечания о наличии в документе библиографии/указателя: [References: 12 tit.].Аудитория: .Тематика: электронный ресурс | труды учёных ТПУ Ресурсы он-лайн:Щелкните здесь для доступа в онлайн
Тэги из этой библиотеки: Нет тэгов из этой библиотеки для этого заглавия. Авторизуйтесь, чтобы добавить теги.
Оценка
    Средний рейтинг: 0.0 (0 голосов)
Нет реальных экземпляров для этой записи

Title screen

[References: 12 tit.]

We present the results of testing a new thermoacoustic sensor designed to detect microwave pulses having durations from 3 to 120 ns at wavelengths of 0.8 and 3 cm. Operation of the sensor is based on the effect of generation of acoustic signals during absorption of microwave pulses in a radiotransparent substrate–absorber–liquid layered structure . A thin nanometer-thick film deposited on a substrate is used as an absorber. Microwaves are converted to an acoustic pulse in the film and the adjacent liquid. The pulse is received by a wideband acoustic receiver and then recorded by a digital oscilloscope. It is shown that for a pulse duration of 120 ns, the shape of the signal recorded by the thermoacoustic sensor completely corresponds to the signal of a tube-diode detector of microwave pulses. The response of the thermoacoustic sensor to shorter pulses (3 and 5 ns long) is a pulse with a duration of 18 ns which is determined by a limited frequency band of the acoustic receiver.

Для данного заглавия нет комментариев.

оставить комментарий.