Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays / D. O. Dolmatov, D. Tarrazo-Serrano, O. V. Minin [et al.]

Уровень набора: SensorsАльтернативный автор-лицо: Dolmatov, D. O., specialist in the field of nuclear technologies, technician of Tomsk Polytechnic University, 1992-, Dmitry Olegovich;Tarrazo-Serrano, D., Daniel;Minin, O. V., physicist, professor of Tomsk Polytechnic University, Doctor of technical sciences, 1960-, Oleg Vladilenovich;Sednev, D. A., specialist in the field of non-destructive testing, assistant of Tomsk Polytechnic University, Associate Scientist, 1989-, Dmitry Andreevich;Filippov, G. A., specialist in the field of non-destructive testing, assistant of Tomsk Polytechnic University, 1991-, German Alekseevich;Minin, I. V., physicist, Senior researcher of Tomsk Polytechnic University, Doctor of technical sciences, 1960-, Igor VladilenovichКоллективный автор (вторичный): Национальный исследовательский Томский политехнический университет, Институт неразрушающего контроля, Международная научно-образовательная лаборатория неразрушающего контроляЯзык: английский.Страна: .Резюме или реферат: Currently, phased arrays have found wide application in ultrasonic nondestructive testing. Volumetric results provided by the inspections with linear phased arrays have low lateral resolution in the elevation direction of such probes. This fact complicates the defects characterization task. In this paper, we suggest the application of the Phase-Reversal Fresnel Zone Plate to increase the resolution of volumetric imaging with linear phased arrays. Application of such plates is aimed at ultrasonic focusing in the elevation plane whereas focusing on the active aperture plane is provided by the application of the Sampling Phased Array. Furthermore, the use of the Phase-Reversal Fresnel Zone Plate is advantageous due to the capability of its 3D printing and introduction to the existing automated testing systems avoiding making changes to the current software and hardware. The effectiveness of the plates was verified experimentally on the existing automated testing system. The obtained experimental results demonstrate that the application of the Phase-Reversal Fresnel Zone Plate allowed achieving the results of the higher resolution as well as improving the signal to noise ratio..Примечания о наличии в документе библиографии/указателя: [References: 21 tit.].Тематика: труды учёных ТПУ | электронный ресурс | automated ultrasonic phased array inspections | 3D ultrasonic imaging | phased array resolution | Phase-Reversal Fresnel Zone Plate | ultrasound focusing | Sampling Phased Array | 3D | фокусировка Ресурсы он-лайн:Щелкните здесь для доступа в онлайн
Тэги из этой библиотеки: Нет тэгов из этой библиотеки для этого заглавия. Авторизуйтесь, чтобы добавить теги.
Оценка
    Средний рейтинг: 0.0 (0 голосов)
Нет реальных экземпляров для этой записи

Title screen

[References: 21 tit.]

Currently, phased arrays have found wide application in ultrasonic nondestructive testing. Volumetric results provided by the inspections with linear phased arrays have low lateral resolution in the elevation direction of such probes. This fact complicates the defects characterization task. In this paper, we suggest the application of the Phase-Reversal Fresnel Zone Plate to increase the resolution of volumetric imaging with linear phased arrays. Application of such plates is aimed at ultrasonic focusing in the elevation plane whereas focusing on the active aperture plane is provided by the application of the Sampling Phased Array. Furthermore, the use of the Phase-Reversal Fresnel Zone Plate is advantageous due to the capability of its 3D printing and introduction to the existing automated testing systems avoiding making changes to the current software and hardware. The effectiveness of the plates was verified experimentally on the existing automated testing system. The obtained experimental results demonstrate that the application of the Phase-Reversal Fresnel Zone Plate allowed achieving the results of the higher resolution as well as improving the signal to noise ratio.

Для данного заглавия нет комментариев.

оставить комментарий.