Submicrosecond electron accelerator based on pulsed transformer / A. V. Poloskov, I. S. Egorov, A. V. Nashilevsky [et al.]
Уровень набора: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated EquipmentЯзык: английский.Страна: .Резюме или реферат: The article describes the test results of a submicrosecond electron accelerator based on a high-voltage pulse transformer. The transformer uses a self-supporting coil design with transformer oil insulation, which ensures high reliability of the device. A transformer-based high-voltage generator produces voltage pulses with an amplitude up to 475 kV, a pulse duration of 0.25 s (FWHM) with a repetition rate up to 5 pps. A vacuum electron diode with a carbon fiber cathode is installed directly at the generator output and provides electron beam current amplitude up to 1.5 kA in the accelerating gap. An exit window with a titanium membrane thick is used to output the electron beam into the atmosphere. The exit window can be replaced by a converter to generate pulsed bremsstrahlung X-rays. The accelerator is designed to carry out research in the fields of studying the properties of materials in extreme conditions and the practical application of a pulsed electron beam..Примечания о наличии в документе библиографии/указателя: [References: 43 tit.].Аудитория: .Тематика: электронный ресурс | труды учёных ТПУ | pulsed electron beam | pulsed electron accelerator | high voltage pulsed transformer | импульсы | электронные пучки | ускорители | импульсные трансформаторы Ресурсы он-лайн:Щелкните здесь для доступа в онлайнTitle screen
[References: 43 tit.]
The article describes the test results of a submicrosecond electron accelerator based on a high-voltage pulse transformer. The transformer uses a self-supporting coil design with transformer oil insulation, which ensures high reliability of the device. A transformer-based high-voltage generator produces voltage pulses with an amplitude up to 475 kV, a pulse duration of 0.25 s (FWHM) with a repetition rate up to 5 pps. A vacuum electron diode with a carbon fiber cathode is installed directly at the generator output and provides electron beam current amplitude up to 1.5 kA in the accelerating gap. An exit window with a titanium membrane thick is used to output the electron beam into the atmosphere. The exit window can be replaced by a converter to generate pulsed bremsstrahlung X-rays. The accelerator is designed to carry out research in the fields of studying the properties of materials in extreme conditions and the practical application of a pulsed electron beam.
Для данного заглавия нет комментариев.