Gaussian Filtered Small-Angle Ultrasonic Computed Tomography Using Linear Arrays : Chap. / Chang Jianglei, A. I. Soldatov, P. V. Sorokin [et al.]

Уровень набора: Progress in Material Science and Engineering / eds. I. V. Minin, S. Uchaikin, A. Rogachev, O. StaryАльтернативный автор-лицо: Chang Jianglei;Soldatov, A. I., specialist in the field of electronics, Professor of Tomsk Polytechnic University, doctor of technical Sciences, 1958-, Aleksey Ivanovich;Sorokin, P. V., specialist in the field of electronics, Associate Professor of Tomsk Polytechnic University, engineer, candidate of technical sciences, 1960-, Pavel Vladimirovich;Kostina, M. A., specialist in the field of electronics, Assistant of the Department of Tomsk Polytechnic University, 1991-, Maria Alekseevna;Soldatov, A. A., specialist in the field of electronics, engineer, Senior Lecturer of Tomsk Polytechnic University, candidate of technical Sciences, 1988-, Andrey Alekseevich;Xu Shupeng, physicist, engineer of Tomsk Polytechnic University, 1993-;Chirjev, A. I., Anatoly InnokentjevichКоллективный автор (вторичный): Национальный исследовательский Томский политехнический университет, Инженерная школа неразрушающего контроля и безопасности, Отделение электронной инженерииЯзык: английский.Резюме или реферат: This paper describes the use of the Gauss filter to improve the quality of the tomogram with the shadow method of ultrasonic testing. The use of a window with different parameters was investigated on a model and tested on experimental data, and its optimal size was determined. The simulation and experimental results are given for one and two reflectors located in the testing zone. The resolution of the system consisting of receiving and transmitting antenna arrays with 16 elements is determined..Примечания о наличии в документе библиографии/указателя: [References: 13 tit.].Аудитория: .Тематика: электронный ресурс | труды учёных ТПУ Ресурсы он-лайн:Щелкните здесь для доступа в онлайн
Тэги из этой библиотеки: Нет тэгов из этой библиотеки для этого заглавия. Авторизуйтесь, чтобы добавить теги.
Оценка
    Средний рейтинг: 0.0 (0 голосов)
Нет реальных экземпляров для этой записи

Title screen

[References: 13 tit.]

This paper describes the use of the Gauss filter to improve the quality of the tomogram with the shadow method of ultrasonic testing. The use of a window with different parameters was investigated on a model and tested on experimental data, and its optimal size was determined. The simulation and experimental results are given for one and two reflectors located in the testing zone. The resolution of the system consisting of receiving and transmitting antenna arrays with 16 elements is determined.

Для данного заглавия нет комментариев.

оставить комментарий.