Electrical discharge drilling of granite with positive and negative polarity of voltage pulses, Electronic resource / A. S. Yudin [et al.]

Уровень набора: International Journal of Rock Mechanics and Mining SciencesАльтернативный автор-лицо: Yudin, A. S., specialist in the field of electrophysics, researcher of Tomsk Polytechnic University, candidate of technical sciences, 1984-, Artem Sergeevich;Zhurkov, M. Yu., electrophysicist, Research scientist of Tomsk Polytechnic University, 1978-, Mikhail Yurievich;Martemyanov, S. M., specialist in the field of electronics, electronics of Tomsk Polytechnic University, Candidate of technical sciences, 1986-, Sergey Mikhailovich;Datskevich, S. Yu., electrophysicist, Associate Scientist of Tomsk Polytechnic University, 1981-, Sergey Yurievich;Vazhov (Vajov), V. F., specialist in the field of power engineering, Associate Professor of Tomsk Polytechnic University, Candidate of technical sciences, 1939-, Vladislav FedorovichКоллективный автор (вторичный): Национальный исследовательский Томский политехнический университет, Инженерная школа новых производственных технологий, Научно-производственная лаборатория "Импульсно-пучковых, электроразрядных и плазменных технологий";Национальный исследовательский Томский политехнический университет, Инженерная школа новых производственных технологий, Отделение материаловедения;Национальный исследовательский Томский политехнический университет, Инженерная школа энергетики, Отделение электроэнергетики и электротехники (ОЭЭ)Язык: английский.Страна: .Резюме или реферат: Electrical discharge drilling is a promising method that allows for the reduction of the costs of well drilling in hard rocks including the energy costs. This paper describes experimental drilling of a well in granite. The well has the diameter of 340 mm and the depth of 15 m, and transformer oil was used as the drilling fluid. In order to study the characteristics of the drilling process and drill string stability we used two drill bits with the interelectrode gaps of 40 mm and 70 mm and applied pulse voltage of positive and negative polarity to the drill bit electrodes. The results are as follows. Increasing the inter-electrode gap has allowed us to reduce the energy costs while increasing the drilling rate, but it has slightly reduced the lifetime of the drill string insulation. The polarity of the voltage pulse has no effect on the penetration rate. At the same time, in the case of negative pulse polarity, the electrical stability of the drill string insulation is higher than that for the positive one. For the 70 mm inter-electrode drill gap, the specific energy consumption and energy input per unit length of the inter-electrode gap are lower while the performance of a single pulse is greater. In this paper we are also discussing the peculiarities and prospects of industrial implementation of electrical discharge drilling. In addition to increasing the overall reliability of the drill string and pulse power source, it is necessary to find suitable insulation material with high flashover resistance in water-based mud..Аудитория: .Тематика: электронный ресурс | труды учёных ТПУ | electrical discharge drilling | pulse polarity | granite | borehole | rate of penetration | электроразрядное бурение | импульсная полярность | гранит | скорость | проникновение Ресурсы он-лайн:Щелкните здесь для доступа в онлайн
Тэги из этой библиотеки: Нет тэгов из этой библиотеки для этого заглавия. Авторизуйтесь, чтобы добавить теги.
Оценка
    Средний рейтинг: 0.0 (0 голосов)
Нет реальных экземпляров для этой записи

Title screen

Electrical discharge drilling is a promising method that allows for the reduction of the costs of well drilling in hard rocks including the energy costs. This paper describes experimental drilling of a well in granite. The well has the diameter of 340 mm and the depth of 15 m, and transformer oil was used as the drilling fluid. In order to study the characteristics of the drilling process and drill string stability we used two drill bits with the interelectrode gaps of 40 mm and 70 mm and applied pulse voltage of positive and negative polarity to the drill bit electrodes. The results are as follows. Increasing the inter-electrode gap has allowed us to reduce the energy costs while increasing the drilling rate, but it has slightly reduced the lifetime of the drill string insulation. The polarity of the voltage pulse has no effect on the penetration rate. At the same time, in the case of negative pulse polarity, the electrical stability of the drill string insulation is higher than that for the positive one. For the 70 mm inter-electrode drill gap, the specific energy consumption and energy input per unit length of the inter-electrode gap are lower while the performance of a single pulse is greater. In this paper we are also discussing the peculiarities and prospects of industrial implementation of electrical discharge drilling. In addition to increasing the overall reliability of the drill string and pulse power source, it is necessary to find suitable insulation material with high flashover resistance in water-based mud.

Для данного заглавия нет комментариев.

оставить комментарий.